Fluke Ti40FT and Ti45FT IR FlexCam® Thermal Imagers with IR-Fusion® Technology
Overview
Features
Specifications
Models and Accessories
Knowledge and Information
Overview
The versatile choice for maintenance and production engineers and technicians
The Fluke Ti4x models feature everything needed for virtually every thermography task. With a 160 x 120 detector and a temperature sensitivity down to 0.08°C (80mK) (NETD) they deliver high resolution images where even the smallest temperature differences can be seen. The units are extremely easy to use through the Windows® CE menu structure and offer an extended troubleshooting feature set to allow on the spot analysis in the field.
The FT models feature the innovative IR-Fusion® technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.
Typical applications:
Predictive maintenance – Identify electrical and mechanical problems before they cause failure
Industrial maintenance – Check whether repairs have been performed successfully
Quality control – Examine prototypes and refine thermal management designs
Process monitoring – Real-time observation to ensure efficient and safe operation
Features
Fluke IR-Fusion Technology
Infrared and Visible light images are fused together - enabling you to view images in a range of modes from full IR to full visible light, and see exactly what you are viewing.
To find out more select "IR-Fusion" in the side navigation of this page.
See exactly what you are viewing Fluke IR-Fusion® technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time.
Large, sharp thermal images Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments.
A sharp image in every situation The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring.
Make anomalies visible Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies.
Analysis and reporting comes standard The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page.
Radiometric measurement – the ‘data behind the picture’ Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software.
•
Ti45FT
Ti40FT
High resolution, low noise VOx detector for high quality images
160 x 120
Temperature range to cover broad industrial applications
-20 to + 600 ° C (-4 to 1112 °F)
High temperature option
1200 ºC (2192 ºF)
•
High thermal sensitivity for viewing even the smallest temperature differences
≤0.08 ºC (80 mK)
≤0.09 ºC (90 MK)
180º articulating flexible lens to view images in every situation
•
•
Choice of 3 interchangeable lenses to cover every application
•
•
Large 5" high contrast color LCD for a clear picture independent of lighting conditions
•
•
Fully radiometric for detailed temperature analysis and tracking
•
•
SmartFocus for best image quality and accurate temperature measurements
•
•
Windows® CE based menu structure for ease of use
•
•
Personalized instrument set-up for multiple use
•
•
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
•
•
SmartView reporting and analysis software included
•
•
AutoCapture for making intermittent problems visible
•
•
On-board analysis functions
•
•
User defined text annotations for simplified reporting
•
•
Built-in visible light (digital) camera
•
•
IR/Visible Alarm function
•
Laser pointer for easy targeting
•
•
Flash and torch light for high quality images in dark environments
Ti45: Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture
Ti40: Full thermal or full visual light. Merge thermal-visual images in SmartView software. Picture-in-Picture
Visible light camera
1280 x 1024 pixels, full color
Visible light digital zoom
Ti45: 2x
Ti40: -
Temperature measurement
Calibrated temperature range
Ti45: -20 ˚C to 600 ˚C (-4 to 1112 ºF) in 3 ranges Ti40: -20 ˚C to 350 ˚C (-4 to 662 ºF) in 2 ranges
Range 1
Ti45: -20 ˚C to 100 ˚C (-4 to 212 ºF)
Ti40: -20 ˚C to 100 ˚C (-4 to 212 ºF)
Range 2
Ti45: -20 ˚C to 350 ˚C (-4 to 662 ºF)
Ti40: -20 ˚C to 350 ˚C (-4 to 662 ºF)
Range 3
Ti45: 250 ˚C to 600 ˚C (482 to 1112 ºF)
Ti40: -
Optional - High temperature
Ti45: Up to 1200 ˚C (2192 ºF) Ti40: -
Range 4
Ti45: 500 ˚C to 1200 ˚C (932 to 2192 ºF)
Ti40: -
Accuracy
±2°C or 2 % (whichever is greater)
Measurement modes
Ti45: Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below
Ti40: Centerpoint, center box (area min/max, average)
Emissivity correction
0.1 to 1.0 (0.01 increments)
Image presentation
Digital display
5" large high-resolution digital display
LCD backlight
Sunlight readable color LCD
Video output
RS170 EIA/NTSC or CCIR/PAL composite video
Palettes
Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
Optional lenses (only available at time of original purchase)
54 mm Telephoto lens
High precision Germanium lens
Field of view (FOV)
9º horizontal x 6º vertical
Spatial resolution (IFOV)
0.94 mrad
Min focus distance
0.6 m
10.5 mm wide angle lens
High precision Germanium lens
Field of view (FOV)
42 º horizontal x 32 º vertical
Spatial resolution (IFOV)
4.9 mrad
Min focus distance
0.3 m
Image and data storage
Storage medium
Compact flash card stores over 1000 IR images (1 GB card standard)
File formats supported
14 bit measurement data included. Exportable JPEG, BMP, PNG, GIF, TIFF.
Interfaces and software
Interface
Compact flash card reader included
Software
SmartView; Full analysis and reporting software included
Laser
Classification
Class II
Laser targeting
Laser dot visible on screen when blending thermal and visible image
Controls and adjustments
Set-up controls
Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
Image controls
Level, span, auto adjust (continuous/manual)
On-screen indicators
Battery status, target emissivity, background temperature and real time clock