Safer than traditional solenoid testers and fully compliant with NFPA 70E*
The T+PRO and T+ Electrical Testers offer all the functionality that electricians look for in volt meters and voltage and continuity testers:
Both have three ways to detect ac/dc voltage: light, sound, and vibration
Both offer the added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight
The T+PRO Electrical Tester comes with a rotary field indicator for troubleshooting three-phase systems, resistance measurement to 9.99 KOhms, as well as a backlit LCD display for easier viewing
Safer than traditional solenoid testers:
Solid-state tester design
CAT IV 600 V, CAT III 1000 V rated
Complies with NFPA 70E*
The ruggedness and reliability that customers have come to expect from Fluke
* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.
Features
Added functionality available only on the T+PRO:
Backlit LCD display for easier viewing
Display resolution of 0.1 V, ideal for troubleshooting low-voltage lighting
Resistance (Ohms) to 9.99 kOhms
Rotary Field Indication
Display Hold for easier viewing in hard-to-test areas
Features and benefits of the T+PRO and T+:
3 forms of ac/dc voltage indication: light, sound, and vibration for added user protection and convenience
Detect live voltage even when the batteries are dead
Extra heavy-duty, replaceable test leads for more flexibility and durability
CAT IV 600 V, CAT III 1000 V rated for added user protection
Continuity beeper
Bright LED flashlight for work in poorly lit areas
GFCI Trip
On/Off switchable beeper, selectable according to your environment
Compliant with latest NFPA 70E recommendations*
Replaceable test probes for added flexibility and convenience
Convenient probe storage on the back
Probe holder for easier testing
Hazardous voltage warning light for added user protection
Test lead strap included for better test lead management
AC/DC Voltage: 12 V – 600 V on LED bar, 10.2 V – 600 V on LCD (LCD on T+PRO only)
Auto-off saves battery power
2-year warranty
* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment
Specifications
Specifications
Temperature
Operating
-10 °C to 55 °C (14 °F to 131 °F)
Storage
-30 °C to 60 °C (-22 °F to 140 °F)
Relative humidity
0 °C to 30 °C (32 °F to 86 °F): 90 %
30 °C to 40 °C (86 °F to 104 °F): 75 %
40 °C to 50 °C (104 °F to 122 °F): 45 %
Altitude
Operating
2,000 m (approx. 6,561.6 ft)
Storage
10,000 m (approx. 32,808.4 ft)
Battery type/life
AAA (2); 40 hours
Shock, vibration
Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
Safety
ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1
Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to NFPA 70E*
AC Bandwidth
45 Hz to 66 Hz
Maximum working voltage
1000 V ac/dc
Maximum measurable voltage
600 V ac/dc
Duty cycle
Indefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off
For voltages above 240 V the tester must connect to a voltage source only for a
MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s