The 7-600 tester is designed for safe, automatic measurements of ac volts, dc volts, resistance and continuity. Simply turn on and use.
Auto Selection simplifies voltage measurements in power environments. When measuring ohms/continuity with more than 4.5 volts present across the input jacks (intentional or not) the meter automatically switches to measuring ac or dc volts, whichever is greater. Input impedance is approximately 2kOhms, helping determine if voltage is from leakage (so-called "ghost" voltages) or a hard connection. Overload protection is provided in all measurement modes.
Features
Features at a glance
AC voltage
DC voltage
Resistance
Continuity Beeper
Auto Selection of volts ac, volts dc, resistance, and continuity
CAT III 600V
Digital display
Two year warranty
Specifications
Technical Data
Voltage DC
Range and Resolution:
40.00V, 400.0V, 600V
Best Accuracy:
±(1.5%+1)
Voltage AC
Range and Resolution:
40.00V, 400.0V, 600V
Best Accuracy:
±(2.9%+3)
Ohms
Range and Resolution:
400.0 Ω
Best Accuracy:
±(1.5%+1)
Safety Specifications
Electrical Safety
Fluke 7-600
EN61010- 1 CAT III 600V
Agency Approvals
UL, CSA, TÜV and VDE listed
Mechanical & General Specifications
Size
Without holster:
142.3 mm L x 70.5 mm W x 34.6 mm D (5.55" L x 2.75" W x 1.35" D)