The i6000sflex is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Features
No features available for this accessory.
Specifications
Electrical Characteristics
Current Ranges
60 A / 600 A / 6000 A ACRMS
Output Sensitivity (AC coupled)
50 mV /5mV / 0.5mV per A
Load Impedance
100 kOhm minimum
Accuracy (at +25°C)
±1% of range (45 – 65 Hz)
Linearity (10% to 100% of range)
±0.2% of reading
Noise
8mV ACRMS (60 A)
2 mV ACRMS (600/6000A)
Frequency Range
10 Hz to 50 kHz (- 3 dB)
Phase Error
< ±1º (45 – 65Hz),
±10º (at 20 kHz)
Position Sensitivity (with cable > 25mm from the coupling)
±2% of range
External field (with cable > 200mm from the head)
±1% of range
Power Supply
2 x AA MN 1500 LR6 alkaline
400 Hours, low battery indicator or dedicated ext power supply