The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
Maximum conductor diameter 178 mm (7 in.)
CAT III 600V safety rating
Features
No features available for this accessory.
Specifications
Electrical specifications
Current ranges
30 A
300 A
3000 A
AC rms
Output sensitivity (AC-coupled)
100 mV
10 mV
1 mV per A
Load impedance
100 kΩ minimum
Accuracy
at +25 °C
± 1 % of range (45 Hz to 65 Hz)
Linearity
10 % to 100 % of range
± 0.2 % of reading
Noise
8 mV ac rms (30 A)
2 mV ac rms (300 A, 3000 A)
Frequency range
10 Hz to 50 kHz (-3 dB)
Phase error
< ± 1 º (45 Hz to 65 Hz)
± 10 º (at 20 kHz)
Position sensitivity
with cable > 25 mm from the coupling
± 2 % of range
External field
with cable > 200 mm from the head
± 1 % of range
Power supply
2 x AA/MN 1500/LR6 Alkaline, , 400 hours, low battery indicator or dedicated external power supply
Temperature Coefficient
± 0.08% of reading per °C
Working voltage
see Safety standards section
600 V AC rms or DC
General Specifications
Head Circumference
610 mm (24 in)
Head cable diameter
14.3 mm (0.56 in)
Head bend radius
38.1 mm (1.5 in)
Cable length (head to electronics)
2 m (6.56 ft)
Output connection
0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
Operating temperature range
-20 °C to +90 °C (-4 °F to 190 °F) (head)
-20 °C to +85 °C (-4 °F to 185 °F) (electronics)
Storage temperature range
-40 °C to +105 °C (-40 °F to 221 °F) (head)
-20 °C to +85 °C (-4 °F to
185 °F) (electronics)
Operating humidity
15 % to 85 % (non-condensing)
Weight
180 g (0.396 lb) (head)
190 g (0.419 lb) (electronics)
Safety standards
BS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 600 V AC rms or dc and frequencies below 1 kHz.