A pack of 3 pieces of the i5s current clamps, specially configured to provide low current accuracy while taking measurements on secondary current transformers. This cost-saving 3-pack is perfect for use with 3-phase tools such as the Fluke 434 or Fluke 435.
Low level current clamp measures up to 5 A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
Features
No features available for this accessory.
Specifications
Specifications
Nominal current range
5 A
Continuous current range
10 mA to 6 A
Maximum
Non-Destructive Current
70 A
Lowest measurable current
10 mA
Basic Accuracy
48 Hz to 65 Hz
10 mA to 1 A
1% + 5 mA
1 A to 5 A
1%
Useable frequency
40 Hz to 5 kHz
Output level(s)
400 mV/A
Input Load Impedance
> 1 MΩ in parallel with up to 47 pF
Crest Factor
≤ 3, add 0.7% to accuracy
Safety Specifications
Safety
CAT III 600 V per IEC/EN61010-1, Pollution Degree 2