The Fluke 368 FC true-rms leakage current clamp meter helps you measure small problems before they become large problems, all without taking equipment off line.
An easy-to-use portable thermal imaging camera, the TiR4FT is specifically designed for building applications.
Minimize Downtime and Take the Mystery Out of Image Analysis
Compact and intuitive, the VT04A and VT04 Visual IR Thermometers blend a visual image with a heat map overlay, to help quickly identify the location of issues
The Fluke CNX™ 3000 Wireless Multimeter lets you work on electrical panels faster, safer, easier. Connect remote modules, view readings from a distance.
The a3004 FC Wireless DC Current Clamp Meter is a fully functional current clamp meter that wirelessly relays measurements to other Fluke Connect® enabled master units.
Combine the functions of a power analyzer, power quality logger, scope, data logger, and clamp meter, for monitoring and troubleshooting electrical loads
AC/DC current module that wirelessly relays measurements from current clamp accessories to other Fluke Connect® enabled master units
A fully functional true-rms current clamp meter that wirelessly relays measurements to other Fluke Connect® enabled master units
Log and analyze measurement inside a closed cabinet.
The a3003 FC wirelessly relays measurements from current clamp accessories to other Fluke Connect® enabled master units.
Record, monitor and evaluate power quality disturbances with the Fluke 1750 including voltage, current, harmonics, transients, waveforms and flicker.
Record three-phase power quality monitoring for power quality disturbances with the new Fluke 1750 Power Recorder and the Fluke Power Analyze software.
Record three-phase power quality monitoring for power quality disturbances with the new Fluke 1750 Power Recorder and the Fluke Power Analyze software.
A fully functional AC voltage meter that wirelessly relays AC voltage measurements to other Fluke Connect® enabled master units
The Fluke 1740 Series three-phase power quality loggers are everyday power meters for technicians who troubleshoot and analyze power quality issues.
The Fluke 368 true-rms leakage current clamp meter helps you detect, document and compare leakage current readings over time without taking equipment off line.
The Fluke CNX™ t3000 K-Type Wireless Voltage Module lets you troubleshoot HVAC systems faster, safer, easier. Record and view readings remotely.
A fully functional DC voltage meter that wirelessly relays DC voltage measurements to other Fluke Connect® enabled master units
2.5 GS/s sampling rate, 200 MHz bandwidth with 2 input channels and DMM for industrial process control, automation or electronic applications.
Maximize productivity with the combined Fluke 287 and FlukeView® Forms Combo Kit. With built-in data logger and TrendCapture capability, the 287 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs.
Combo kit with the Fluke 87V Industrial Multimeter, heavy duty test leads, alligator clips and test probes, hanging strap, case.
Automotive Multimeter - Fluke 233 with removable display allows you to connect to one point of the car and read results in another. Learn More.
Stay safe with the insulated hand tools starter kit + the top selling Fluke 87V Industrial Multimeter. The set comes wiht 5 insulated screwdrivers and 3 insulated pliers. Lifetime warranty.
Combo kit includes Fluke 87V industrial multimeter, i400 AC current clamp and accessories.
The Fluke 289 electronics multimeter allows you to log and zoom in on problems. Now compatible with the Fluke Connect mobile app.
The Fluke 287 electronics multimeter allows you to log and zoom in on problems. Now compatible with the Fluke Connect mobile app.
The Fluke 376 FC True-RMS Clamp Meter combined with the insulated tools starter kit, the most often used screwdrivers, pliers and cutters.
Maximize productivity with the combined Fluke 289 and FlukeView® Forms Combo Kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs.
Double insulated voltage probe for ScopeMeter 190 series.
Double insulated voltage probe for ScopeMeter 190 series.
Double insulated voltage probe for ScopeMeter 190 series. Each probe set includes:600 V CAT III / 1000 V CAT II rated 10:1 Voltage
Double insulated voltage probe for ScopeMeter 190 series
Double insulated voltage probe for ScopeMeter 190 series.Each probe set includes: ...
Limiting workers’ exposure to electrical hazards like arc flash or electrocution is a solid foundation for any electrical safety program. Combine that mindset with the right non-contact tools and more electrical workers will be kept out of harm’s way.
A digital multimeter is essentially a voltage-measuring tool with some current abilities. A clamp meter is basically a current-measuring tool with some voltage abilities. They are distinctly different instruments, each with its own advantages.
As California approaches a state-wide mandate to add solar to all new residential construction, the skilled labor gap and solar installation expertise will be top of mind.
Promotion Description Eligible customers who participate in this Inspect Your Gadgets promotion (the “Promotion”) during the Promotion Period (as defined in Section 3) and meet all the requirements as set forth in these terms and conditions of the Promotion are eligible to receive a gift, further described below. Under the Promotion, eligible customers of Fluke Electronics Corporation or Fluke Electronics Limited Partnership (“Sponsor”) who purchase a “Qualifying Fluke Product”...
The Fluke 15x7 Series Insulation Multimeter is a new category of test tool that combines a full featured True RMS DMM and a megohmmeter. It's an integrated tool for maintaining and troubleshooting motor systems, electrical distribution, and production equipment.
MetalTech produces steel sheets. Maintenance technicians use the Fluke 1587 Insulation Multimeter to troubleshoot and maintain the equipment.
This article demonstrates how to detect the 13 most common causes of winding insulation and bearing failure in advance.
The 975 gathers ten fundamental IAQ parameters: Temperature, Humidity, Dew Point Temperature, Web Bulb Temperature, Carbon Dioxide, Carbon Monoxide, Air Velocity, Air Volume, and Percentage of Outdoor Air (calculated from temperature or CO2). This application note reviews those parameters and the associated functions on the 975. For more detailed information, see other app notes from the Fluke HVAC/IAQ library.
HVACR mechanics rarely rely on a single test to pass or fail a function or process. As they walk up to a condensing unit, they listen, they wave their hand over the condenser discharge air, and then they grab the suction line, the liquid line, and the discharge line (and wish they hadn't done that). All of this before they even open their tool box.
Preventing motor failure problems will extend the operating life of system equipment. Insulation resistance testers can be used to determine the integrity of windings or cables in motors, transformers, switchgear, and electrical installations.
As founder and CEO of Mark Snyder Electric, 43-year solar professional, and holder of eight (so far) patents and patents pending for new energy efficiency technologies, Master Electrician and Forensic Electrical Specialist Mark Snyder has seen the solar industry develop from a few panels on a handful of California homes to one of the fastest-growing sectors in the world. He’s also seen the growing pains caused by solar’s explosive growth over the last decade: the immense demand for PV...
Motor drives are a ubiquitous technology for transforming the constant voltage from the main ac power supply into a voltage that varies to control motor torque and speed ideal for motors that are driving mechanical equipment loads.
In Part I of this short application note series, we discussed inspection points on motors to make during an energy audit or other efficiency program. Part I covers basic motor efficiency strategy and describes tests and cost savings for voltage and current unbalance and for power factor. Part II covers inspection points that are best incorporated into regular, long-term preventive maintenance.
How to protect yourself from the dangers of counterfeit Fluke products. How to ensure that you purchase genuine Fluke items and what to do if you believe you have.
One would be hard-pressed to find a facility manager who doesn’t want maintenance operations to run as smoothly as possible. Detecting signs of motor components failure becomes easier when combined with a preventive vibration program.
Avoiding arc flash hazard at an asphalt plant where safety is a top expectation, with the use of Fluke wireless tools.
Technology has improved to the point where maintenance technicians can use the same techniques and tools to troubleshoot as well as to inspect, log and share—the basics of proactive maintenance.
Continuously monitoring asset health is critical to avoiding unplanned downtime. Fluke devices help you track conditional change 24/7 and are easy to install.
In any electrical installation, some current will flow through the protective ground conductor to ground. This is usually called leakage current. Leakage current most commonly flows in the insulation surrounding conductors and in the filters protecting electronic equipment around the home or office. So what’s the problem? On circuits protected by GFCIs (Ground Fault Current Interrupters), leakage current can cause unnecessary and intermittent tripping. In extreme cases, it can cause a rise in voltage...
Motor insulation testing of motor windings, baselining and data collection is an important step in preventive maintenance. Fluke insulation testing tools such as the Fluke 1587 FC Insulation Multimeter is an easy way to collect data and analyze trends.
Some Norma 4000 and 5000 instruments require attention due to a calibration error of the external probe (EXT.Shunt- BNC) inputs of instruments caused by incorrect data being written into the instrument at production. This error only affects the current probe inputs of the instruments in the 100mV range and only specific serial numbers (you will have been contacted by Fluke if this affects you). Please follow the steps below to fix the calibration data for all customers if you have been contacted...
Without an effective grounding system, we could be exposed to the risk of electric shock, not to mention instrumentation errors, harmonic distortion issues, power factor problems and a host of possible intermittent dilemmas. If fault currents have no path to the ground through a properly designed and maintained grounding system, they will find unintended paths that could include people. Learn about grounding, and testing with the Fluke 1625.
This application note was written to provide you with an understanding of the basic principles of fossil fuel heating systems and how to troubleshoot these systems using thermometers, digital multimeters (DMMs), pressure/vacuum modules and other accessories.
Early in December 2005, an electrician performing a zero energy check on a circuit at the DOE´s Fernald Environmental Management Project, a former nuclear fuel production facility northwest of Cincinnati, was burned by an arc flash. He escaped severe injury, but the incident focused attention on the digital multimeter that failed and caused the accident. Read how Paul Case, Hanford Electrical Safety Program Coordinator, and veteran of over 30 years in the industry, developed the Hanford Electrical Safety Program following a series of electrical safety incidents in the early 1990s.
Measuring ac and dc voltage and current - you´ve got that. But what about the other features that your DMM has - do you ever use them? Min/Max/Avg is an especially useful but often overlooked aspect of your tool. Learn how to use these to capture a wide range of signal anomalies such as multiple cycle sags or swells, unexpected signal fluctuations, or other types of unattended monitoring of a signal over time.
Electrical energy is the driving force of today´s world. It is available almost everywhere you go, and is capable of driving all sorts of equipment from heating and cooking equipment, through motors and ventilators to the PC that this application note is written on.
Several Fluke DMMs, digital thermometers, and process meters can log detailed min/max and event data. Fluke View Forms software makes it possible to download data logged over time, from multiple locations and test tools, and analyze it on your desktop computer. Graphs and reports make it easy to spot intermittents and other problematic events that may not be otherwise traceable. Fluke View Forms reports are also an efficient way to document processes to meet regulatory standards.
Automatic event capturing—find intermittent events quickly without searching through masses of data.
Oscilloscopes are much easier to use than they used to be, and they´re ideal for tracking down intermittents and electronic signal issues. This application note is a introduction to oscilloscope measurement theory for new users. It explains sampling, triggering, setup parameters, waveform types, and basic troubleshooting.
This application note was written to provide you with an understanding of the basic principles of fossil fuel heating systems and how to troubleshoot these systems using thermometers, digital multimeters (DMMs), pressure/vacuum modules and other accessories.
Several Fluke DMMs, digital thermometers, and process meters can log detailed min/max and event data. Fluke View Forms software makes it possible to download data logged over time, from multiple locations and test tools, and analyze it on your desktop computer. Graphs and reports make it easy to spot intermittents and other problematic events that may not be otherwise traceable. Fluke View Forms reports are also an efficient way to document processes to meet regulatory standards.
The key to detecting intermittents is either being present to witness the event, or using a tool that can take regular readings. This article explains how to use the MIN MAX AVG Recording Mode on the 170 series and 180 series DMMs to identify intermittents.
Testing Functions Case Study: When set to Min/Max, the Fluke 116 can lock in on the numbers as they change faster than the naked eye. This allows one to focus on making a safe measurement, instead of directing attention to the readout. The temperature probe of the 116 allows you to diagnose thermal issues.
Looking for short intermittent interferences? Trendplot™ and ScopeRecord make it easier.
Fluke seminar attendees are provided this form so they can request a completion certificate. Forms are sent into the Fluke Plymouth office and are created/distributed from there.
Compact and rugged, the Fluke 1740 Series three-phase power quality loggers are everyday instruments for technicians who troubleshoot and analyze power distribution systems. Capable of simultaneously logging up to 500 parameters for up to 85 days and capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.
Compact and rugged, the Fluke 1740 Series three-phase power quality loggers are everyday instruments for technicians who troubleshoot and analyze power distribution systems. Capable of simultaneously logging up to 500 parameters for up to 85 days and capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.